Product model:UL2095
| Style 2095 | ||
| Multiple-conductor cable using non-integral jacket | ||
| RATING | ||
| 80 deg C, 300 Vac, Horizontal flame. | ||
| CONDUCTOR | ||
| 32 AWG minimum, solid or stranded. | ||
| INSULATED CONDUCTOR | ||
| Labeled or complying with manufacturer's AWM procedure. | ||
| ASSEMBLY | ||
| Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. | ||
| COVERING | ||
| Optional. | ||
| SHIELD | ||
| Optional. | ||
| JACKET | ||
| Extruded PVC. | ||
| Diameter of cable under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.350 inch or less | 15 mils | 12 mils |
| 0.351 - 0.700 inch | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| *Major diameter if cable is flat or oval. | ||
| BRAID | ||
| Optional. | ||
| STANDARD | ||
| Appliance Wiring Material UL 758. | ||
| MARKING | ||
| General. | ||
| USE | ||
| Internal wiring of electronic equipment and appliances. Tags may indicate the following: "600 volts Peak for Electronic use only". | ||