Product model:UL2517
| Style 2517 | |||
| Multiple-conductor cable using non-integral jacket | |||
| RATING | |||
| 105 deg C, 300 Vac, Cable Flame. | |||
| INSULATED CONDUCTOR | |||
| Labeled or complying with Manufacturer's AWM Procedure. 40 AWG minimum. | |||
| ASSEMBLY | |||
| Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | |||
| COVERING | |||
| Optional. | |||
| SHIELD | |||
| Optional. | |||
| JACKET | |||
| Extruded PVC. | |||
| Diameter of Core Assembly under Jacket@ | Minimum Average Thickness | Minimum Thickness at any point | |
| 0.700 inch or less | 30 mils | 24 mils | |
| 0.701 - 1.000 inch | 45 mils | 36 mils | |
| 1.001 - 1.500 inch | 60 mils | 48 mils | |
| 1.501 - 2.500 inch | 80 mils | 64 mils | |
| @ - Major diameter if cable is flat or oval. | |||
| BRAID | |||
| Optional. | |||
| STANDARD | |||
| Appliance Wiring Material UL 758. | |||
| MARKING | |||
| General. | |||
| USE | |||