Product model:UL2785
| Style 2785 | |||
| Multiple-conductor cable using non-integral jacket. | |||
| RATING | |||
| 60 deg C, 300 Vac, Horizontal flame. | |||
| INSULATION | |||
| Labeled or complying with Manufacturer's AWM Procedure | |||
| ASSEMBLY | |||
| Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. the conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | |||
| SHIELD | |||
| Optional. | |||
| COVERING | |||
| (Optional) - A 6 mil or heavier extruded PVC covering may be extruded over the conductor assembly. | |||
| JACKET | |||
| Extruded PVC | |||
| major dia in inches | |||
| 0.250 or less | 15 mils min average | 12 mils minimum at any point | |
| 0.25l-0.700 dia | 30 avg | 24 min | |
| 0.701-1.000 dia | 60 avg | 48 min | |
| l.00l-l.500 dia | 80 avg | 64 min. | |
| STANDARD | |||
| Appliance Wiring Material UL 758. | |||
| MARKING | |||
| General. | |||
| USE | |||
| Internal wiring of Electronic Equipment. | |||