Product model:UL2789
| Style 2789 | |||
| Multiple Conductor Cable with Extruded Non-integral Jacket | |||
| RATING | |||
| 60 deg C, 30 Vac, Cable flame. | |||
| INSULATED CONDUCTOR | |||
| Labeled or complies with this Manufacturers AWM singles Procedure. | |||
| ASSEMBLY | |||
| Two or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly. | |||
| COVERING | |||
| Optional, extruded PVC, 5 mils minimum thickness at any point, over the conductor assembly or extruded PTFE, PFA, FEP or ETFE, 8 mils minimum average thickness, 6 mils minimum thickness at any point. | |||
| SHIELD | |||
| Optional. | |||
| COVERING | |||
| Optional, extruded PVC, 5 mils minimum thickness at any point, over the conductor assembly or extruded PTFE, PFA, FEP or ETFE, 8 mils minimum average thickness, 6 mils minimum thickness at any point. | |||
| SHIELD | |||
| Optional. | |||
| JACKET | |||
| Extruded PVC. | |||
| Major diameter of assembly under jacket* | Minimum average thickness | Minimum thickness at any point | |
| 0.700 inch or less | 30 mils | 24 mils | |
| 0.701-1.000 inch | 45 mils | 36 mils | |
| 1.001-1.500 inch | 60 mils | 48 mils | |
| 1.501-2.500 inch | 80 mils | 64 mils | |
| 2.501-4.000 inch | 110 mils | 88 mils | |
| 4.001 inch or larger | 140 mil | 112 mils | |
| * - Major diameter if cable is flat or oval. | |||
| STANDARD | |||
| Appliance Wiring Material UL 758. | |||
| MARKING | |||
| General. | |||
| USE | |||
| Internal Wiring and External Interconnection in Class 2 Circuits of Electronic Equipment. | |||