Product model:UL2960
| Style 2960 | ||||
| Multiple conductor cable using non-integral jacket. | ||||
| RATING | ||||
| 60 deg C, 30 Vac, Horizontal flame for Construction A, Cable flame for Construction B. | ||||
| CONDUCTOR | ||||
| 32 AWG minimum, solid or stranded. | ||||
| INSULATION | ||||
| Extruded PP or extruded PE, 3.5 - 30 mils thickness. | ||||
| ASSEMBLY | ||||
| Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | ||||
| COVERING | ||||
| Optional. Extruded PVC, 6 mil may be extruded over the conductor assembly. | ||||
| SHIELD | ||||
| Optional. | ||||
| JACKET | ||||
| PVC, thickness in accordance with the table below. | ||||
| Construction A | Construction B | |||
| Dia of Cable under Jacket@ | Min average | Min at any point | Min average | Min at any point |
| 0.250 inch or less | 15 mils | 12 mils | 30 mils | 24 mils |
| 0.251-0.425 inch | 30 mils | 24 mils | 30 mils | 24 mils |
| 0.426-0.700 inch | 45 mils | 36 mils | 45 mils | 36 mils |
| @ - Major dia if cable is flat or oval. | ||||
| STANDARD | ||||
| Appliance Wiring Material UL 758. | ||||
| MARKING | ||||
| General. | ||||
| USE | ||||
| Construction A - Internal wiring of electronic equipment (such as computers and electric business machines). Construction B - External interconnection of electronic computers and electric business machines. | ||||